Triple-pole switch disconnector type OM and fuse switch disconnector type OMB for indoor installation 12 i 24 kV

Indoor switch disconnectors type OM, OMB are designed for application in the indoor switchboards of rated voltage 7,2 - 24kV and are using for switchiong-on and switching-off of the currents that are not greater than swithboard rated continuous current. In open condition the safe insulation gap in the circuit is provided.

Contact: Piotr Haczyk , Krzysztof Ratowicz

CONSTRUCTION AND OPERATING PRINCIPLE:
Switch disconnectors type OM have secant construction and is based on modular principle. The basic unit consist a frame with insulators and current carrying parts. A triple pole earthing switch as easily as fuse base can be fitted.Stored spring energy operating mechanism with a snap action mechanism is mounted on the frame. To ensure correct operation for all relevant currents, the switch disconnector system OM/OMB is equipped with an arc extinguishing system. When interrupting the current, a current independent air blast automatically starts at the correct time during the interrupting process. This is achieved by designing the insulators on the opening side as cylinder with pistons. The pistons are connected to the mechanism in the same way as the moving contacts. The air blast therefore starts simultaneously with the contact movement (autopneumatic air blast). The switch disconnectors may be opened and closed by the following operating mechanisms: - electric, type NSW30; - manual, type NR-1. As a standard, the mechanism is equipped with 1400mm length isolating rod. Accessories such as shunt trip (220VAC, 110VAC, 220VDC, 110VDC) and auxiiliary switch ŁK - 15 can easily be added.

CHARACTERISTIC FEATURES:

  • Modular principle
  • Motor driven operating mechanism type NSW30
  • High durability and reliability (1000kVA transformer protection)
  • Version with capacitive insulator (12 - 17,5 - 24 kV ) available
  • Good technical parameters
  • Compact construction

    SWITCH DISCONNECTOR TYPE OM USE FOR STATION TOWER:

    » OM-24/160 or 275 with no earthing switch inside station tower
    » OM-24/UD/160 or 275 with earthing switch inside station tower
    » OM-24/160 or 275 with no earthing switch out of station tower
    » OM-24/UD/160 or 275 with earthing switch out of station tower

    DIMENSIONAL DRAWING (AutoCad2000) OF TYPICAL MV INDOOR SWITCH DISCONNECTORS FOR 24 kV

    » OM-24/160
    » OM-24/UD/160
    » OM-24/UG/160
    » OMB-24/BD/160
    » OMB-24/BD/UD/160
    » OMB-24/BG/160

    » OM-24/275
    » OM-24/UD/275
    » OM-24/UG/275
    » OMB-24/BD/275
    » OMB-24/BD/UD/275
    » OMB-24/BG/275

    » OM-24/T/160
    » OM-24/T/UD/160
    » OM-24/T/UG/160
    » OMB-24/T/BD/160
    » OMB-24/T/BDT//UD/160

    DIMENSIONAL DRAWING (AutoCad2000) OF TYPICAL MV INDOOR SWITCH DISCONNECTORS FOR 12 kV

    » OM-12/125
    » OM-12/UD/125
    » OM-12/UG/125
    » OMB-12/BD/125
    » OMB-12/BD/UD/125
    » OMB-12/BG/125

    » OM-12/185
    » OM-12/UD/185
    » OM-12/UG/185
    » OMB-12/BD/185
    » OMB-12/BD/UD/185
    » OMB-12/BG/185

    » OM-12/T/125;
    » OM-12/T/UD/125;
    » OM-12/T/UG/125;
    » OMB-12/T/BDT/125

    <<BACK